Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 105 of 140 items found.

  • Heavy Duty Hot Wire Thermo-Anemometer

    Extech 407123 - Extech Instruments Corporation

    The 407123 Heavy Duty Hot Wire Thermo-Anemometer uses a telescoping probe (extends up to 2 ft) which is ideal for use in ducts and ventilating systems. It can accurately measure Air Velocity and Temperature and simultaneously displays them on the dual LCD. Additional functions include Data Hold and Min/Max measuring modes. Comes complete with telescoping probe with 5.5ft cable, and 6 x AA batteries.

  • PCIe-8433, PCI Express, 2-Port, Isolated, RS485/RS422 Serial Interface Device

    781745-01 - NI

    The PCIe‑8433/2 is a high-performance industrial interface for high-speed, port‑to‑port isolated communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.

  • PXI-8431, 4-Port, RS485/RS422 PXI Serial Interface Module

    778985-01 - NI

    4-Port, RS485/RS422 PXI Serial Interface Module - The PXI‑8431/4 is a high-performance interface for high-speed communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.

  • PXI-8431/2 , 2-Port, RS485/RS422 PXI Serial Interface Module

    778984-01 - NI

    2-Port, RS485/RS422 PXI Serial Interface Module - The PXI‑8431/2 is a high-performance interface for high-speed communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.

  • PCI-4070, 6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device

    778275-01 - NI

    The PCI‑4070 is a high-performance DMM that provides the measurement capabilities found in two common test instruments: a high-resolution DMM and a digitizer. As a DMM, the PCI‑4070 delivers fast, accurate AC/DC voltage, AC/DC current, 2‑ or 4‑wire resistance, and frequency/period measurements, as well as diode tests. In the high-voltage, isolated digitizer mode, the PCI‑4070 can acquire waveforms at sample rates up to 1.8 MS/s.

  • PCI-8433, 4-Port, PCI, Isolated, RS485/RS422 Serial Interface Device

    779146-01 - NI

    The PCI‑8433/4 is a high-performance industrial interface for high-speed, port‑to‑port isolated communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.

  • - RS-232 to RS-422/RS-485 Concentrator - Wiring Hub

    Model 290 - Telebyte, Inc.

    FEATURES: Break RS-485 Limit, Expand to 496 Nodes 16 Port Capacity; Each Port Settable to RS-422 or 2 Wire RS-485; Provides Isolation Between Ports; All Ports Surge Protected; Increased System Reliability. The Model 290 RS-232 to RS-422/RS-485 Concentrator offers a unique group of features for those applications using RS-422 and/or RS-485 for communications between a multiplicity of devices.

  • Mezzanine System

    5047 - Abaco Systems Inc

    The 5047 provides breakout of all ECM signals for debug, design validation and development. Plated through holes on the PCB allow soldering of probe wires to IO, Data, Power and Serial Identification signals. LEDs indicate presence of 3V, 5V, +12V, -12V and Ground. Elevates the ECM module by 2 mm and saves wear on the ECM carrier board connectors. Since this is a debug too there is no serial identification circuit.

  • Length Network Cable Tester

    SC-8108 - Comunion Technology Co., Ltd.

    1. Measure network cable length and determine the distance of breakage point.2. Check wiring error in 5E, 6E, coaxial cable, such as open circuit,short circuit, jumper wire, reverse connection .3. Portable unit with long battery life (wait-case 50 hours).4. Automatically time-delay shut off.5. Self-checking and automatically compensate any change in battery capacity or ambient temperature.

  • DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER

    TURNS-LCRTZ - Vasavi Electronics

    Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.

  • 8 Channels, RTD Measurement

    RT1 - North Atlantic Industries

    The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.

  • Bench Type Panel Meter

    ED-205 - Standard Electric Works Co., Ltd

    ● Dimension:91(L) × 103(W) × 100(D)mm● Deflection Angle : 90°● Scale Length:Approx. 65mm ● Terminal: 4mm socket captive head, suitable for wire or pin-type test lead.● Material And Color: Acrylic resin meter cover, white scale plate, plastic stand in black.● Safety Standard: IEC/EN 61010-1 CAT Ⅱ 300V EN 61326-1 EN 61000-4-2 EN 61000-4-3

  • PXI-8433, 4-Port, Isolated, RS485/RS422 PXI Serial Interface Module

    779539-01 - NI

    4-Port, Isolated, RS485/RS422 PXI Serial Interface Module—The PXI‑8433/4 is a high-performance industrial interface for high-speed, port‑to‑port isolated communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.

  • PXI-8433, 2-Port, Isolated, RS485/RS422 PXI Serial Interface Module

    779744-01 - NI

    2-Port, Isolated, RS485/RS422 PXI Serial Interface Module - The PXI‑8433/2 is a high-performance industrial interface for high-speed, port‑to‑port isolated communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.

  • PXI-2529, 128-Crosspoint, 2-Wire PXI Matrix Switch Module

    778739-01 - NI

    The PXI‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXI‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

Get Help